Commercial Hydronic Radiators

Hot Spring

General

Brilliantly imaginative, the mesmerizing and stylish design of the Hot Spring captures a tightly coiled elegance in reflected light.

 

Model:
Height:
Diameter:
Depth:

HOT 60
25.6″
7.8″
11.0″

HOT 180
72.8″
7.8″
11.0″


Heat Output:

Hydronic
Heat Output @180°F
1975* BTUH 6681* BTUH
*chrome finish reduces radiator output by 20%
Pair of chrome angle shut-off valves included

Calculating BTUH Output for Different Water Temperatures

The BTUH outputs are listed for 180° water. The following chart may be used to calculate the BTUH outputs for different water temperatures:

Water Temperature Multiply the Listed BTUH output (180°) by:
120° 0.38
130° 0.48
140° 0.57
150° 0.67
160° 0.78
170° 0.89
180° 1
190° 1.13

 

To size the radiators it is necessary to calculate a house’s heating requirement.  This calculation measured in BTU/Hour should be done on a room-by-room basis either by a heating contractor or qualified plumber. The following are some estimates of Heat Requirements for Sample Cities:

 

City: BTUH per sq. foot:
Boston 40
Chicago 40
Denver 40
New York City 40
Philadelphia 35
Portland, OR 25
San Francisco 25
Seattle 25
Toronto 40
Washington, D.C. 35

Colors & Finishes